sun EcoVantage Mobile Catalog


Home: EcoVantage Mobile Catalog: Electronics: Converters:

Newmar DC Coverters
Cat. No. NM-C

Convert 20-50 VDC to 12 VDC negative ground output for powering communication/navigation
equipment, on negative ground systems. Ideal for powering voice and data transceivers in mobile applications.

• Excellent Regulation: Output voltage maintained within 1% under all line and load conditions within rating (except 3 amp models).
• Heat generated by semi-conductors is extracted and dissipated by large heat sink fins that maximize air contact for cool operation and long life of components.
• Polyurethane conformal coating on PC boards and corrosion-resistant anodized aluminum case with heavy duty shock mounts assure survival in hostile environments.
• Numerous converter and load protection circuits: Current limiting*; automatic thermal shutdown; short circuit proof*; reverse polarity and over voltage protection*.
* Except 3 Amp. Model.

Download PDF Data Sheet

Model
Input
voltage
Output
voltage
Output Amps
Case
Size
Weight
Intermittent
Continuous
(Lbs)
(Kg.)
Standard Series
32-12-3
20-40†
13.6
3
2
C-1
2
.9
32-12-6
20-50
13.6
6
6
C-10
2.5
.9
32-12-10
20-50
13.6
10
10
C-2
4
1.8
32-12-15
20-50
13.6
15
15
C-2
5
2.3
32-12-25
20-50
13.6
25
20
C-3
7.5
3.4
32-12-35
20-50
13.6
35
30
C-4
12
5.5
32-12-50
20-50
13.6
50
40
C-5
16
7.3

Performance Specifications – Standard & Isolated Series
Output: 13.6 VDC (internally adjustable 12.6-14.5)
Ripple: 150 mV P-P maximum
Regulation: 1% Line/Load (32-12-3)
Duty Cycle Ratings*
Intermittent - 20 minutes max on time, 20% duty. Current limit set at approx. 105% of intermittent rating
Continuous - 24 hours, 100% duty
Idle Current: Less than 100 mA (including power “ON” light )
Operating Temp: 0-50° C, Derate Linearly From 100% @ 40° C To 50% @ 50° C Thermal shutdown @ 70° C Case Temperature
Switching Frequency: 40 Khz*
Efficiency: 85% - Typical.†
Isolation:
Output/Chassis; Input/chassis: 250 VDC
Certification: Carries the CE mark

*except 32-12-3 – Linear, Non-Switching
†except 32-12-3– 50% @ 24 VDC Input