SURGE PROTECTION
PRODUCTS FOR RV’S
PROTECT your on board or carry on Electric & Electronic Devices
from Harmful Lightning & Power Surges with Lectra Shield!
Lectra Shield LS E120 Hybrid Parallel
Hardwire Power Surge Protector is a 3 wire device with an LED
indicator, reacts fast, clamps tight, provides 100,000 amps of surge
current
protection and is designed to automatically reset after each surge with
in ratings for 120 Volt AC 30 Amp applications can be installed in an
RV or an RV Pedestal
Lectra Shield LS E240 Hybrid Parallel
Hardwire Power Surge Protector is a 4 wire device which can also be
used for 3 wire applications by tying it’s white Neutral & green
Ground wire together & connecting it to Neutral, Ground, or a
Neutral/Ground bond-ed connection, with an LED indicator for each
phase, reacts fast, clamps tight, provides 200,000 amps of surge
current protection, 100,000 amps per phase & is designed to
automatically reset within ratings for 240 Volt AC Power 50 Amp
applications can easily be installed In an RV or an RV Pedestal.
Lectra Shield LS E120 Hybrid Parallel
Maximum Surge Current (8x20?s): 100,000 Amps Total |
Maximum Operating Voltage: 120 Volts AC |
Maximum Surge Voltage (1.2x50?s): 20,000 Volts |
Typical Leakage Current <5? amps |
Clamping Voltage: 130 Volts RMS |
Operation Temperature: - 40 to +85°C |
Clamping Response Time: <5 nanoseconds |
Connectors: 3 Wire 14 AWG |
Current: Non-Load Bearing |
Lines Protected: L-N, N-G, L-G |
VPR Rating: 600/600/1000 |
Installation Configuration: Parallel |
Design: Hybrid |
Weight: 1 lb. |
Operation Indicators: 1 LED |
Dimension: Depth 2.25" Width 2.844" |
ETL Listed: Conforms to ANSI/UL 1449 3rd Ed. Standard |
Dimension: Length 5.694” (including tabs) |
Lectra Shield LS E240 Hybrid Parallel
Maximum Surge Current (8x20?s): 200,000 Amps Total | Maximum Operating Voltage: 120/240 Volts AC |
Maximum Surge Voltage (1.2x50?s): 20,000 Volts | Typical Leakage Current: <5? amps |
Clamping Voltage: 250 Volts RMS | Operation Temperature: - 40 to +85°C |
Clamping Response Time: <5 nanoseconds | Connectors: 4 Wire 12 AWG |
Current: Non-Load Bearing | Lines Protected: L-N, L-G, N-G, L-L |
VPR Rating: 900 L-N/800 L-G/1200 N-G /1200 L-L | Installation Configuration: Parallel |
Design: Hybrid | Weight: 1 lb. |
Operation Indicator: 2 LEDs 1 per phase | Dimension: Depth 2.25" Width 2.844" |
ETL Listed: Conforms to ANSI/UL 1449 3rd Ed. Standard | Dimension: Length 5.694” (including tabs) |
|