Home: EcoVantage Mobile Catalog: Electronics: Inverters Grid tied:
SMA America LLC STP60-US-10, 60KW Cat. No. STP60-US-10 | $13,128.82 |
sunny tripower 60-us
The efficient solution for medium to large-scale PV Plants
The new Sunny Tripower 60-US is part of an innovative, global system
solution for commercial and utility PV plants. This solution
combines the advantages of a decentralized system layout with the
benefits of centralized inverter designs which results in
the best of both worlds. High efficiency, easy installation, simple
commissioning and low maintenance requirements contribute
decisively to reducing the operating costs for the entire plant.
The new SMA system solution consists of three components: highly
efficient Sunny Tripower 60-US inverters, the SMA Inverter Manager and
the LCS commissioning tool. It is precisely this systemized approach
that makes the Sunny Tripower 60-US so unique and ensures a high level
of performance
Technical data | Sunny Tripower 60-US |
Input (DC)
|
Max. input voltage | 1,000 V |
MPP voltage range | 570 V to 800 V @400 VAC, 685 V to 800 V @480 VAC |
Min. input voltage | 565 V @400 VAC, 680 V @480 VAC |
Max. input current / short-circuit current | 110 A / 150 A |
Number of independent MPP inputs / strings per MPP input | 1/1 (split up by external PV array junction box) |
Output (AC)
|
|
Rated power at nominal voltage | 60,000 W |
Max. apparent AC power | 60,000 VA |
Output Phases / line connections | 3 / PE |
Nominal AC voltage | 400 V, 480 V |
Nominal AC voltage range | 352 V to 440 V @400 VAC, 423 V to 528 V @480 VAC |
AC power frequency | 50 Hz, 60 Hz |
Rated power frequency / rated grid voltage | 50 Hz, 60 Hz / 400 V, 480 V |
Max. output current | 3 x 87 A @ 400 V, 3 x 72 A @ 480 V |
Power factor at rated power/displacement power factor adjustable | 1/0.8 lagging ... 0.8 leading |
Feed-in phases / connection phases | 3 / 3 |
Efficiency
|
Max. efficiency / CEC @ 400 VAC / CEC @ 480 VAC | 98.8% / 98.0% / 98.5% |
Data Sheet
|
|
|