The Model 091-191-115 Power Save Timer limits the duty
cycle of an A.C. load to 1 hour "ON" and 1 hour "OFF". In normal
operation, the load runs continuously. Continuous operation in most
cases is not necessary, and only consumes power. The Power Save Timer
reduces the ON time to 50% thus cutting power consumption in half. A
bypass switch may be installed to permit full time operation when full
power operation is desired.
- 30A relay, 120V operation
- Automatic 1 hour "On"/"Off" cycle
- Ideal for cycling power to block heaters, reducing power consumption costs:
Typical block heater draws 1200W, use of Power Save Timer reduces average load to 600W
- Indicator light displays when in 'Power Save' mode
- Input for bypass switch for easy setting of full time operation when desired
- Compact plastic case
- 3 year warranty
Input Voltage: 120 Vac
Input Current: 20 ma - Heater "ON",
5 ma - Heater "OFF"
Relay Contacts: 30 Amps
Weight: 1 lbs
Warranty: 3 Years
Power Save Timer, 091-191-115.pdf (107 Kb)
|