The Combination Slide-out Controller with
Voice functions as three controllers. It independently controls two lock
arm motors and a slide-out motor. The controller depends on several inputs:
Lock Arm 1 Switch, Lock Arm 2 Switch, Slide-out Switch, MPX Switch, and an
Ignition Input Signal, which is used to lock out control module.
Product Description
These controllers are designed to control the operation of a slide out room
electrical mechanism. To operate the room, the owner would simply press and
hold the button in the desired direction(In or Out). With the jumper in the
default setting, there is delay in operation of the slide-out to allow for
a voice announcement that the slide-out is in motion. The motion of the slide-out
may be stopped at any time by releasing the button. When the slide out reaches
it's outer most limit, the unit will sense the rise in current and switch
off the power to the slide out motor. To move the room back in again, the
owner will press and hold the button in the desired direction. Again, there
is a short delay in operation of the slide- out to allow for a voice announcement
that the slide- out is in motion. When the slide out reaches it's inner most
position, the controller will sense the rise in current and will shut off
power to the motor. Direction control is accomplished by using the rocker
switch terminated at the MPX Bus input. The module operates by sensing the
voltage on the MPX bus input. As the switch is depressed (In or Out direction)
each function sends a different load to the module which in turn interprets
the direction of travel. The Current Adjust is used to prevent damaging the
motors or opening of the fuse or circuit breaker for the slide-out unit.
If the current exceeds a preset level, the module shuts off. To restart the
motor, press the switch in the another direction.
Features & Benefits
- Designed To Control The Operation Of A Slide Out Room Electrical Mechanism
- To Operate The Room, The Owner Would Simply Press And Hold The Button
In The Desired Direction
- When The Slide Out Reaches It's Outer Most Limit, The Unit Will Sense
The Rise In Current And Switch Off The Power To The Slide Out Motor
- To Move The Room Back In Again, The Owner Will Press And Hold The Button
In The Desired Direction
- When The Slide Out Reaches It's Inner Most Position, The Controller
Will Sense The Rise In Current And Will Shut Off Power To The Motor
- No Supplier Warranty
00-00971-100,
Slide Out Control Module; Use With Intellitec Monoplex ™ System; Motor Control
With Voice Output; 10 To 16 Volt DC/ 10 To 35 Amp
00-00971-200
Slide Out Control Module; Use With Intellitec Monoplex ™ System; Motor Control
With Voice Output; 10 To 16 Volt DC/ 5 -15 Amp
|