Home: EcoVantage Catalog: Solar: Charge Controllers:

SmartHarvest 50V Maximum Power Point Tracking (MPPT) charge controller
Cat. No. SCCP05
Weight 3 lbs

PWM charge controllers are an elegant, proven system solutions.  SmartHarvest's SCCP05-050 scales this economical solution for use in small PV systems dedicated to specific applications, such as powering a light, an appliance or charging a back-up battery system connected to a smart phone, PC, wireless network adapter or other critical electronic device.
PWM charge controllers use advanced digital signal processing to anticipate battery charging needs and affect the right amount of control.  They are an excellent choice for smaller systems operating under consistent solar conditions where utilizing economical PWM technology helps allocate more of the system budget to other areas such as energy storage.  The SCCP05-050 is the perfect charging solution when performance and economics are of equal priority.

Please note SmartHarvest by OutBack products are not designed for connection with OutBack communication devices. For more information on product capability, please contact sales or technical support.



 SMARTHARVEST SPECIFICATIONS SCCP05-050
SCCP10-050
Maximum Output Current (I)510
Nominal Battery Voltages12/24
Input Panel Power (Wp)60/120120/240
Panel IntelligencePWM
Maximum Input Voltage (Voc)25/50
Charging RegulationFour stages: bulk, absorb, float and equalization
Bulk Voltage (VDC)Flooded: 14.8/29.6 VRLA: 14.6/29.2 
Absorb Voltage (VDC)Flooded: 14.8/29.6 VRLA: 14.4/28.8 
Absorb Time2 hours 
Float Voltage (VDC)Flooded: 13.2/26.4 VRLA: 13.5/27.0 

Equalization Voltage (VDC)
(Flooded Batteries Only)

Flooded: 15.5/31.0 

Equlaization Time

1 hour 

State of Charge Low Voltage
Disconnect (V)

11.4/22.8V

Low Battery Load Reconnect (VDC)

12.4/28.4 

High Battery Load Disconnect (VDC)

15.0/30.0
Temperature Compensation-5mV/°C
Battery Type Selection
VRLA/Flooded—selectable via jumper.  Factory default VRLA (jumper inserted)
Data LoggingAvailable with monitoring software.
Standby Current (mA)6.8
Display3 LEDs
IP ClassIP20
Operating Temperature Range-40° to 60° C
Humidity0-95% RH non-condensing
Dimensions HxWxD (in/cm)2.6x6.3x1.0 / 6.8x15.9x2.52.6x6.3x1.0 / 6.8x15.9x2.5
Weight (lb/kg).39 / .18 
CertificationsCE, IEC/EN 62109-1
WarrantyStandard 2 year