Home: EcoVantage Catalog: Electronics: Inverters Battery Base:
OutBack VFX Series Sine Wave Inverter Cat. No. 551INVTVFX Weight 60 lbs | |
The new OutBack VFX series is a ventilated version of our
original sealed FX series modular "building block” sine wave
inverter/charger that can be used for both small and large power
systems. By allowing cooler outside airflow through the internal
electronics, more AC power is available and operation in extremely hot
environments is improved compared to the sealed FX series.
Each OutBack FX or VFX inverter/charger is a complete power conversion
system - DC to AC inverter, battery charger and AC transfer switch.
Additional FX inverter/chargers can be connected at any time in either
parallel (120 VAC), series (120/240 VAC), or three-phase (120Y208 VAC)
configurations. This allows a system to be tailored to meet the
specific power conversion requirements of the application, both at the
time of the installation and in the future.
The OutBack VFX series is also available in export versions with 230
VAC, 50 hz output that can be connected in parallel (230 VAC) or in
three phase (230Y400 VAC) configurations. Like the FX series, the
OutBack VFX is also designed to survive harsh environments around the
world. The full sreened vent openings are "bug-proof" and the die-cast
aluminum chassis protects and keeps the power conversion components
cool in very hot environments even when operated at high power for
extended periods. The VFX can be used in high ambient applications up
to 60oC (with reduced output ratings).
The OutBack VFX series inverter/charger system is designed for both
residential and commercial stand-alone or back-up power applications
with battery energy storage. It is designed to operate as a coordinated
system with the other OutBack products i.e. the PSDC, PSAC and PSR
enclosures as well as the MX60 MPPT charge controllers and MATE system
controller and display.
Vented Construction Features:
Powdercoated all aluminum die-cast chassis
Internal electronic components are cooled by outside air
Stainless steel screen to protect air intake and internal fan
UL 94V0 plastic vent grills to protect the air exhaust. All openings
are 0.0025 inches square to keep out dirt, bugs, and other critters –
we call it “bug proof” construction
Air inlet comes with removable, washable foam filter insert to trap small particles
Conformal coated circuit boards to resist corrosion
Higher output power when inverting or battery charging when compared with the sealed FX inverter versions
Designed to allow easy field servicing and repair
Ideal Applications:
Montana or Arizona etc. where salt air is not a problem and climate is dry
More watts per dollar
Installations where well protected environments are available
Specifications
|
VFX
2812
|
VFX
3524
|
VFX
3648
|
VFX2612E
|
VFX
3024E
|
VFX
3048E
|
Continuous
Power Rating at 25 degrees C
|
2800
VA
|
3500
VA
|
3600VA
|
2600VA
|
3000VA |
3000VA |
Nominal
DC Input Voltage
|
12
VDC
|
24
VDC
|
48
VDC |
12
VDC |
24
VDC
|
48
VDC |
Nominal
AC Input Voltage / Frequency
|
120V
60 Hz
|
120V
60 Hz |
120V
60 Hz |
230V
/ 50Hz |
230V
/ 50Hz |
230V
/ 50Hz |
Continuous
AC RMS Output current at 25 C
|
23.3
amps
|
29.2
amps
|
30
amps |
11.3
amps
|
13
amps
|
13
amps |
Idle
Power (typical at no AC load) (sleep – 3 watts)
|
19-21
Watts
|
18-20
Watts
|
21-23
Watts |
18-20
Watts
|
18-20
Watts |
21-23
Watts
|
Efficiency
(typical at 25 degree C and 75% resistive load)
|
>90%
|
>90%
|
>90%
|
89%
|
90%
|
90% |
Total
Harmonic distortion voltage (typical / max)
|
2%
/ 5%
|
2%
/ 5%
|
2%
/ 5%
|
2%
/ 5%
|
2%
/ 5% |
2%
/ 5% |
Output
Voltage Regulation
|
+/-
2% typ.
|
+/-
2% typ
|
+/-
2% typ
|
+/-
2% typ
|
+/-
2% typ |
+/-
2% typ |
Surge
Power Capability Peak (1mSec)
|
56
amps AC
|
70
amps AC
|
70
amps AC |
35
amps AC
|
35
amps AC |
35
amps AC |
Surge
Power Capability RMS (100mSec)
|
40
amps AC
|
50
amps AC
|
50
amps AC |
20
amps AC
|
25
amps AC |
25 amps AC |
Overload
Capability (from 25 C start) 5 second
|
4000
VA
|
5000
VA
|
5000
VA
|
4000
VA
|
4800
VA |
4800
VA |
Overload
Capability (from 25 C start) 30 minutes
|
3200
VA
|
4000
VA
|
4000
VA
|
3100
VA
|
3300
VA
|
3300
VA
|
Automatic
AC transfer Relay (at nominal AC)
|
60
amps AC
|
60
amps AC |
60
amps AC |
30
amps AC
|
30
amps AC |
30
amps AC |
AC
Input Current (adjustable limits)
|
60
amps AC
|
60
amps max
|
60
amps max
|
30
amps max
|
30
amps max |
30
amps max |
AC
Input Voltage Range (adjustable limits)
|
90-140
VAC
|
200-260
VAC
|
200-260
VAC
|
200-260
VAC
|
200-260
VAC |
200-260
VAC |
Frequency
Range – AC Input
|
54-67.4
Hz
|
40
to 60 Hz
|
40
to 60 Hz
|
40
to 60 Hz
|
40
to 60 Hz |
40
to 60 Hz |
DC
Input Range (adjustable low battery cut-out)
|
10-16.5
VDC
|
20-33
VDC
|
40-66
VDC
|
10–16.5
VDC
|
20
- 33 VDC
|
40
- 66 VDC |
Recommended
DC Breaker
|
OBDC-250
|
OBDC-250
|
OBDC-175 |
OBDC-175 |
OBDC-250
|
OBDC-175 |
Continuous
Battery Charger Output amps DC
|
125
amps DC
|
85
amps DC
|
45
amps DC |
125
amps
|
85
amps |
45 amps |
Shipping
Weight
|
60
Lbs
|
60
Lbs
|
60
Lbs |
60
Lbs |
60
Lbs |
60
Lbs |
|
|
|