Home: EcoVantage Catalog: Electronics: Inverter Small:
Exeltech XP125 Sinewave Inverter Cat. No. ELX-XP125 Weight 8 lbs | |
Made in America, EXELTECH XP SERIES
INVERTERS are the most affordable, reliable, lightweight and best
regulated, true sine wave inverters available. The XP SERIES inverter
will operate any AC load anywhere. Ultra lightweight, yet rugged enough
for the most extreme mobile environments, and are UL listed to 1950 for
telecom applications.
Exeltech XP125 Sinewave
Inverter 125 Watt
DC INPUTS (12 VDC - 108 VDC): a 6' non-terminated, two
conductor power cord is provided. Insulation on the negative
(-)conductor is
black and insulation on the positive (+) conductor is red. Cigarette
Lighter connection Available on 12 Volt Models only (not UL listed)
AC OUTPUTS:one
NEMA-15 outlet (standard wall receptacle) is located on the Front Panel.
LOW BATT /
THERM BUZZER ; produces an audible alarm if DC input voltage
falls to a level within 2% to 4% of the low limit of inverter, or, if
there is an over temperature condition.
OVER VOLTAGE
PROTECTION: If input voltage to the inverter exceeds set limits,
the inverter will immediately and without warning shut off. When input
voltage returns to normal range, the inverter will immediately restart.
Since high over voltages tend to have very fast edges, the inverter
must shut down quickly to protect itself. This kind of fault usually
occurs if the battery is suddenly disconnected from the system and the
battery charger continues to supply current.
UNDER
VOLTAGE PROTECTION: When battery voltage falls to within 2% to
4% of low line voltage, the LOW BATT / THERM buzzer will sound. If the
condition continues without reducing load to the inverter or adding
charge to the battery, the inverter will shut off. When voltage rises
to approximately 95% of nominal battery voltage, the inverter will turn
back on and the alarm condition will clear. The inverter can be
manually reset by cycling the on/off switch. This will reset the
protection circuitry and turn the inverter on at any voltage above
minimum voltage.
MODEL
|
NORMAL
VDC
|
MINIMUM
VDC
CUT-OFF / ALARM
|
MAXIMUM
VDC
|
RATED
CURRENT
|
PEAK
CURRENT
|
XP-125
/ 12VDC
|
13.8
VDC
|
10.4
/ 10.6 VDC
|
16.5
VDC
|
12.3
A
|
13.9
A
|
XP-125
/ 24VDC
|
27.6
VDC
|
19
/ 21 VDC
|
33
VDC
|
6.1
A
|
7 A
|
XP-125
/ 48VDC
|
55.2
VDC
|
41.5
/ 42.5 VDC
|
62
VDC
|
3.1
A
|
3.5
A
|
XP-125
/ 66VDC
|
75.9
VDC
|
57.5
/ 58.5 VDC
|
91
VDC
|
2.2
A
|
2.5
A
|
XP-125
/ 108VDC
|
124.0
VDC
|
94
/ 95 VDC
|
149
VDC
|
1.4
A
|
1.6
A
|
|
|
|